To maintain consistent data standards, the Waka Kotahi NZ Transport Agency controls and maintains lookup codes that are used to describe various elements of the road corridor. This page lists the lookup codes that have recently been added to the state highway database.
You can access all current and up to date data collection forms and lookup codes on the MyRoads wiki. These lookup forms are automatically updated from RAMM at the beginning of every month. If you are entering data during a lookup update cycle, you can refresh the spreadsheet to obtain all RAMM lookup codes current to that date. You can do this by clicking on Data > Refresh All.
A full list of lookup codes can be viewed directly in the state highway database or by following the My Roads wiki link above.
If there is no allowable code available for the data you are collecting or updating or you have a question about existing codes, please contact the Data Management Team at National Office, email sm050@nzta.govt.nz to log the request.
If you'd like to be notified when new lookup codes are added to this page, please register your interest by emailing to sm050@nzta.govt.nz
Invert Lining Code: GFP
Invert Lining Description: Glass Fibre Reinforced Plastic
Asset type code | Asset type description |
---|---|
DRBZ | Basal drainage |
DRCF | Counterfort drain |
DRCT | Crest drain |
DRCO | Cut-off drain |
DRHZ | Horizontal drain |
DRSL | Slope drain |
DRTE | Toe drain |
DRHB | Hybrid/Other |
Diameter code | Diameter description |
---|---|
000 | 0mm |
050 | 50mm |
100 | 100mm |
150 | 150mm |
Drainage owner code | Drainage owner description |
---|---|
NZTA | NZ Transport Agency |
JOINT | Joint Ownership (NZTA and KiwiRail) |
Asset type code | Asset type description |
---|---|
GTICC | Concrete columns |
GTIWD | Vertical drain (wick drains) |
GTIVD | Vertical drain (other) |
GTISC | Stone columns |
GTILW | Lightweight fill |
GTIPY | Polystyrene (used for fill) |
GTIMR | Rafting (mining) |
GTIGR | Raft (geosynthetics) |
GTISK | Shear key |
GTIGA | Ground anchors |
GTIGT | Geotextile |
GTIGG | Geogrids |
GTIHB | Hybrid/Other |
GTSNL | Soil nails |
GASBL | Geothermal/Gas blankets |
Ground treatment owner code | Ground treatment owner description |
---|---|
NZTA | NZ Transport Agency |
JOINT | Joint Ownership (NZTA and KiwiRail) |
Asset type code | Asset type description |
---|---|
RFFM | Fixed Mesh |
RFDM | Drape |
RFEM | Erosion Matting (MacMat R) |
RFSL | Shallow Landslide Barrier |
RFAT | Attenuator |
RFBF | Rockfall (Barrier) Fence |
RFDB | Debris Flow Barrier (Fence) |
RFHB | Hybrid |
RFM | Multiple Systems |
RFBD | Rockfall Bund |
RFDBB | Debris Flow Barrier (Bund) |
RFBW | Rockfall Wall |
RFCD | Catch Ditch |
RFSR | Rockfall Shelter |
RFSH | Shotcrete |
RFRB | Rock Bolts (Anchors) |
RFSC | Scaling |
RFMO | Monitoring |
Asset form code | Asset form description |
---|---|
T | Terramesh type structure |
G | Geogrid structure |
E | Earth (unreinforced) |
C | Concrete block |
NA | Not applicable |
Rockfall protection owner code | Rockfall protection owner description |
---|---|
NZTA | NZ Transport Agency |
JOINT | Joint Ownership (NZTA and KiwiRail) |
Geotechnical structures (less than 1.5m in height) will be populated in the Retaining wall table. The following asset codes and types have been added to the retaining wall type lookup table.
Asset type code | Asset type description |
---|---|
GSSBW | Sandbag wall |
GSRRW | Railway iron wall |
GSPPW | Timber pole and panel wall |
GSMWS | MSE wall (steel strap) |
GSMWG | MSE wall (geosynthetic) |
GSMSS | MSE slope (steel strap) |
GSMSG | MSE slope (geosynthetic) |
GSMOO | MSE other (geotechnical) |
GSHPW | H-Pile wall |
GSCBW | Concrete block wall |
GSBOW | Stone or boulder wall |
GSTCW | Crib wall (geotechnical) |
GSGAW | Gabion wall (geotechnical) |
GSWOW | Geotechnical wall (other) |
Old Asset Type | Old External ID | Description | New Asset Codes | New Asset Type | New External ID | New Asset Sub Type |
Cameras |
1ANPR |
ANPR Camera |
CAM |
Cameras |
ANPR |
Automatic Number Plate Recognition |
Cameras |
1CCTVCAM |
CCTV Camera |
CAM |
Cameras |
CCTV |
Fixed CCTV |
Cameras |
1PTZCAM |
CCTV PTZ Camera |
CAM |
Cameras |
PTZ |
Pan Tilt Zoom |
NEW |
CAM |
Cameras |
REDLT |
Red Light |
||
NEW |
CAM |
Cameras |
THRM |
Thermal Camera |
||
Cabinet and Equipment |
6MATRXSW |
Matrix Switch |
TRAN |
Communications and Transmission |
ANAVSW |
Analogue Video Matrix Switch |
Other |
8CABLE |
Cabling |
TRAN |
Communications and Transmission |
CABLE |
Cables – Copper |
Emergency Phone |
2EMGSM |
Emergency Phone VCE GSM |
TRAN |
Communications and Transmission |
EMETS |
Emergency Telephone System |
Cabinet and Equipment |
6EES |
Ethernet Edge Switch |
TRAN |
Communications and Transmission |
ESWCH |
Ethernet Switches |
NEW |
TRAN |
Communications and Transmission |
FIBRE |
Fibre |
||
Cabinet and Equipment |
6MEDCON |
Media Converter |
TRAN |
Communications and Transmission |
MEDCON |
Media Converter |
Cabinet and Equipment |
6VDSLMOD |
VDSL Modem |
TRAN |
Communications and Transmission |
MODEM |
Modem |
Cabinet and Equipment |
6MULTPLX |
Multiplexer |
TRAN |
Communications and Transmission |
MULTPLX |
Multiplexer |
Cabinet and Equipment |
6SERIAL |
Serial Server |
TRAN |
Communications and Transmission |
SERIAL |
Serial Server |
Cabinet and Equipment |
6HUB |
Wireless Hub |
TRAN |
Communications and Transmission |
HUB |
Wireless Device |
Cabinet and Equipment |
6OHDSCON |
OHDS Controller |
DCON |
Device Controllers |
PLCON |
PLC Controller |
Cabinet and Equipment |
6REBOOT |
Remote Reboot Unit |
DCON |
Device Controllers |
REBOOT |
Remote Reboot Unit |
Cabinet and Equipment |
6CHASRAC |
Chassis Rack |
DCON |
Device Controllers |
RDSC |
Road Side Controller |
NEW |
DCON |
Device Controllers |
SIGCON |
Signal Controller |
||
Cabinet and Equipment |
6VMSMAST |
VMS Controller - Master |
DCON |
Device Controllers |
VMSC |
VMS Controller Cards |
Barriers |
5AUTOBAR |
Automated Barriers |
EGTE |
Electronic Barriers and Gates |
AUTOBAR |
Automated Barriers |
Barriers |
5EMERGT |
Emergency Access Gate |
EGTE |
Electronic Barriers and Gates |
AUTOCG |
Automatic Traffic Control Gates |
NEW |
EGTE |
Electronic Barriers and Gates |
FLASH |
Flashing Beacons |
||
Electronic Signs |
3AWS |
Advanced Warning Sign |
ESIG |
Electronic Signs |
AWS |
Advanced Warning Sign |
NEW |
ESIG |
Electronic Signs |
BEND |
Bend Warning Sign |
||
Electronic Signs |
3CMS |
Changeable Message Sign |
ESIG |
Electronic Signs |
CMS |
Changeable Message Sign |
Electronic Signs |
3MVMS |
Mobile VMS (MVMS) |
ESIG |
Electronic Signs |
MVMS |
Mobile VMS |
Electronic Signs |
3SCHOOL |
School Zone Sign |
ESIG |
Electronic Signs |
SCHOOL |
School Zone Sign |
Electronic Signs |
3SID |
Speed Indication Device |
ESIG |
Electronic Signs |
SID |
Speed Indication Device |
Electronic Signs |
3VMS |
Variable Message Sign |
ESIG |
Electronic Signs |
VMS |
Variable Message Sign |
Cabinet and Equipment |
6FULATMS |
Full Size ATMS Cabinet |
ENCL |
Enclosures |
ATMS |
Full Advanced Traffic Management Systems |
Cabinet and Equipment |
6LSUCON |
LSU Power Enclosure |
ENCL |
Enclosures |
LSUP |
Gantry Mounted |
Cabinet and Equipment |
6MINATMS |
Mini ATMS Cabinet |
ENCL |
Enclosures |
MINI |
Mini ATMS |
Cabinet and Equipment |
6REGVMS |
Regional VMS Cabinet |
ENCL |
Enclosures |
REGVMS |
Regional VMS |
Cabinet and Equipment |
6SIGCAB |
Signal Controller Cabinet |
ENCL |
Enclosures |
SIGCAB |
Signal Controller |
Other |
8TDC |
Traffic Data Collection |
ENCL |
Enclosures |
TMS |
Traffic Monitoring System |
NEW |
ENVSN |
Environmental Sensors |
FLOW |
Flow Detector |
||
NEW |
ENVSN |
Environmental Sensors |
HYDR |
Hydrocarbon Sensor |
||
Environmental Monitoring |
4ENVIRO |
Environmental Station |
ENVSN |
Environmental Sensors |
ENVRO |
Environmental Station |
Environmental Monitoring |
4HUMID |
Humidity Device |
ENVSN |
Environmental Sensors |
HUMID |
Humidity Sensor |
Detection Services (Non Camera) |
7ICE |
Ice Detection System |
ENVSN |
Environmental Sensors |
ICE |
Ice Detection System |
Environmental Monitoring |
4RAIN |
Rainfall Meter |
ENVSN |
Environmental Sensors |
RAIN |
Rainfall Meter |
Environmental Monitoring |
4SOUND |
Sound Device |
ENVSN |
Environmental Sensors |
SOUND |
Sound Measuring Device |
Environmental Monitoring |
4TEMP |
Temperature Device |
ENVSN |
Environmental Sensors |
TEMP |
Temperature Sensor |
Environmental Monitoring |
4WIND |
Wind Monitor |
ENVSN |
Environmental Sensors |
WIND |
Wind Monitor |
NEW |
PWR |
Power Supply |
CABLE |
Cables |
||
NEW |
PWR |
Power Supply |
FULC |
Fuel Cell |
||
NEW |
PWR |
Power Supply |
GENSETS |
Gensets |
||
NEW |
PWR |
Power Supply |
INVR |
Inverters |
||
NEW |
PWR |
Power Supply |
LOVPW |
Low Voltage Power |
||
NEW |
PWR |
Power Supply |
TRNF |
Transformers |
||
Cabinet and Equipment |
6BATT |
Battery |
PWR |
Power Supply |
BATT |
Battery |
Cabinet and Equipment |
6ISOTRAN |
Isolating Transformer |
PWR |
Power Supply |
ISTRN |
Isolating Transformer |
Cabinet and Equipment |
6SOLAR |
Solar Panel |
PWR |
Power Supply |
SOLAR |
Solar Panel |
Cabinet and Equipment |
6STNDUPS |
Standard UPS |
PWR |
Power Supply |
UPWS |
Uninterrupted Power Supply |
NEW |
SIGL |
Signals |
LANE |
Lane Lighting |
||
Electronic Signs |
3LSU |
Lane Signal Units |
SIGL |
Signals |
LSU |
Lane Signal Units |
Other |
8TRAFSH |
Traffic Signal Head |
SIGL |
Signals |
TRAFSIG |
Traffic Signals |
Electronic Signs |
3VMSS |
Variable Mandatory Speed Sign |
SIGL |
Signals |
VMSS |
Variable Mandatory Speed Signs |
Electronic Signs |
3VSS |
Variable Speed Sign |
SIGL |
Signals |
VSS |
Variable Speed Signs |
Detection Devices (Non Camera) |
7CONLID |
Continuous Inductive Loop Detector |
VDPR |
Vehicle Sensors and Detection Processors |
INDLP |
Inductive Loop Detector |
Detection Devices (Non Camera) |
7LOOP |
Loop |
VDPR |
Vehicle Sensors and Detection Processors |
LOOP |
Inductive Loops |
Detection Devices (Non Camera) |
7RADAR |
Radar |
VDPR |
Vehicle Sensors and Detection Processors |
RADAR |
Radar |
Detection Devices (Non Camera) |
7OHDET |
Over Height Detection Beam Sensor |
VDPR |
Vehicle Sensors and Detection Processors |
VDPA |
Vehicle Detection Processor/Aggregator |
Other |
8WIREVEH |
Wireless Vehicle Tracking Systems |
VDPR |
Vehicle Sensors and Detection Processors |
WIRVH |
Wireless Vehicle Tracking Systems |
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
BLUTOTH |
Bluetooth Detector |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
DIGAC |
Distributed Acoustic Sensing |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
LGHT |
Light Sensitive Detection |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
LOCALC |
Local Cell |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
MAGM |
Magnetometers |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
PZOD |
Piezo Detector |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
RFID |
Radio Frequency Identification |
||
NEW |
VDPR |
Vehicle Sensors and Detection Processors |
TUBES |
Tubes |
Changes to ITS Assets effective from 17 September 2019.
CloseCode: HUME
Description: Humes
Code: CONT
Description: Connectics
Code: CORY
Description: Cory’s Electrical
Code: CLDG
Description: Clear Digital
New ITS Asset Makes
Asset ID: 153
Description: Humes
Asset ID: 154
Description: Orion
Asset ID: 155
Description: IPS Group
Asset ID: 156
Description: Sika
Asset ID: 157
Description: Vivotech
All changes effective from 12 May 2021.
Close
Line company code |
Description |
Action |
AL |
Alpine |
NEW |
AU |
Aurora |
NEW |
BT |
Buller Electric Power Trust |
NEW |
CN |
Central Lines |
NEW |
CP |
CountiesPower |
NEW |
EA |
EA Networks |
NEW |
ES |
Eastland |
NEW |
LI |
The Lines Company |
NEW |
ML |
Marlborough Lines |
NEW |
MP |
MainPower |
NEW |
NP |
NorthPower |
NEW |
NT |
Network Tasman |
NEW |
ON |
OtagoNet |
NEW |
OR |
Orion |
NEW |
PN |
PowerNet |
NEW |
SP |
ScanPower |
NEW |
ST |
Southland |
NEW |
TP |
Top Energy |
NEW |
UN |
Unison |
NEW |
VE |
Vector |
NEW |
WA |
Waipa |
NEW |
WE |
Wellington Electricity |
NEW |
WL |
WEL Network |
NEW |
WP |
Westpower |
NEW |
WT |
Waitaki |
NEW |
Close
Cost code | Cost description | Activity code | Activity description | Changes |
---|---|---|---|---|
IT | ITS | CABINET | Cabinet and equipment | Made inactive |
IT | ITS | ENCLOSURES | Enclosures | NEW – supersedes CABINET |
IT | ITS | DETDEV | Detection devices | Made inactive |
IT | ITS | DCON | Device controllers | NEW – supersedes DETDEV |
IT | ITS | EBARRIER | Electronic barrier and gates | Changed description |
IT | ITS | EMONITOR | Environmental monitoring | Made inactive |
IT | ITS | ESENSORS | Environmental sensors | NEW – supersedes EMONITOR |
IT | ITS | PHONE | Emergency phone | Made inactive |
IT | ITS | COMS | Communications and transmissions | NEW – supersedes PHONE |
IT | ITS | VEHSEN | Vehicle sensors and detection processors | NEW |
IT | ITS | POWER | Power supply | NEW |
These changes are effective from 15 June 2020.
CloseCost code | Cost description | Fault code | Fault description | Changes |
---|---|---|---|---|
BR | Bridge Maint | BOLTING | Tunnel bolting | Made inactive |
BR | Bridge Maint | PANELS | Panel maintenance (tunnels) | Made inactive |
BR | Bridge Maint | SAFETY | Safety | Made inactive |
BR | Bridge Maint | WORN | Worn or degraded | NEW |
BR | Bridge Maint | BRREP | Bridge repair | Made inactive |
IT | ITS | CORRECTIVE | Corrective maintenance | NEW |
IT | ITS | REINSTATE | Re-instatement | NEW |
IT | ITS | RELOCATE | Relocation | NEW |
IT | ITS | DVTEL | DVTEL maintenance | Made inactive |
IT | ITS | NEW | New | Made inactive |
IT | ITS | OTHER | Other issue | Made inactive |
TF | Traff Facil | RENEW | Renew | Made inactive |
VG | Verge | VEGCNTRL8 | Vegetation control type 8 | NEW |
These changes are effective from 15 June 2020.
CloseCode: HP
Description: High Performance Multi Dot
Explanation: Thermoplastic – Hot and Paint Application with Glass Beads
Changes effective from 3 March 2020.
CloseCode: M12B
Description: Ramp Gore Area
Explanation: Border lines and chevrons in the gore areas of motorway/expressway exits.
Light Model
Light Make: AEC
Light Model: TZHI
Description: TZero HID-S-IN
Explanation: Use with 250w or 400w HPS
Light Make: AEC
Light Model: TZFL
Description: TZero FLU-S-IN
Explanation: Use with 2 x 58w fluoro lamps
These changes are effective from 1 June 2021.
Light Make | Description | Explanation | Light Model | Description | Explanation |
AEC |
AEC |
|
A2 |
A2 LED |
Supplier - Techlight Ltd / Pedestrian only |
AEC |
AEC |
|
IT1S |
ITALO 1 - STA 1 |
Supplier - Techlight Ltd / Pedestrian only |
AEC |
AEC |
|
IT17 |
ITALO 1 - 7SS |
Supplier - Techlight Ltd / Pedestrian only |
AEC |
AEC |
|
IT1 |
ITALO 1 |
Supplier - Techlight Ltd / Vehicle only |
AEC |
AEC |
|
IT2 |
ITALO 2 |
Supplier - Techlight Ltd / Vehicle only |
AEC |
AEC |
|
IT3 |
ITALO 3 |
Supplier - Techlight Ltd / Vehicle only |
AEC |
AEC |
|
LS45 |
LED-in (ST) 4.5 |
Supplier - Techlight Ltd / To be phased out late 2015 / Vehicle Only |
AEC |
AEC |
|
LS47 |
LED-in (ST) 4.7 |
Supplier - Techlight Ltd / To be phased out late 2015 / Vehicle Only |
AEC |
AEC |
|
LO45 |
LED-in (OC) 4.5 |
Supplier - Techlight Ltd / To be phased out late 2015 / Cycle lanes & Pedestrians only |
AEC |
AEC |
|
LO47 |
LED-in (OC) 4.7 |
Supplier - Techlight Ltd / To be phased out late 2015 / Cycle lanes & Pedestrians only |
CREE |
Cree |
|
LED2 |
LEDway XIL02 |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
LED4 |
LEDway XIL04 |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
LED7 |
LEDway XIL07 |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
LED1 |
LEDway XIL10 |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
SQR |
EDGE Square |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
RND |
EDGE Round |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
XSP1 |
XSP1 |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
XSP2 |
XSP2 |
Supplier - Advanced Lighting Technologies Ltd |
CREE |
Cree |
|
XSP3 |
XSP1 3M |
Supplier - Advanced Lighting Technologies Ltd / Pedestrian Only |
IGUZ |
iGuzzini |
|
WOW |
Wow |
Supplier - ECC Lighting Ltd / Pedestrian Only |
IGUZ |
iGuzzini |
|
WOOD |
Woody |
Supplier - ECC Lighting Ltd / Pedestrian Only |
KTL |
KTL |
|
B28F |
Shard-P B28-F |
Supplier - KTL Technologies Ltd /LL17056 optic only / Pedestrian Only |
ROAD |
LED Roadway |
|
ST24 |
Satellite SAT-24S |
Supplier - Energy Light Ltd / To be phased out late 2015 / Pedestrian Only |
ROAD |
LED Roadway |
|
ST48 |
Satellite SAT-48S |
Supplier - Energy Light/ To be phased out late 2015 |
ROAD |
LED Roadway |
|
ST72 |
Satellite SAT-72M |
Supplier - Energy Light Ltd / To be phased out late 2015 / Vehicle Only |
ROAD |
LED Roadway |
|
ST96 |
Satellite SAT-96M |
Supplier - Energy Light Ltd / To be phased out late 2015 / Vehicle Only |
ROAD |
LED Roadway |
|
NX12 |
NXT-12S |
Supplier - Energy Light Ltd / Pedestrian Only |
ROAD |
LED Roadway |
|
NX24 |
NXT-24S - 4AH |
Supplier - Energy Light Ltd / Pedestrian Only |
ROAD |
LED Roadway |
|
NX36 |
NXT-36S |
Supplier - Energy Light Ltd / Vehicle Only |
ROAD |
LED Roadway |
|
NX48 |
NXT-48M |
Supplier - Energy Light Ltd / Vehicle Only |
ROAD |
LED Roadway |
|
NX60 |
NXT-60M |
Supplier - Energy Light Ltd / Vehicle Only |
ROAD |
LED Roadway |
|
NX72 |
NXT-72M |
Supplier - Energy Light Ltd / Vehicle Only |
OTEK |
OrangeTek |
|
MX1 |
Terraled Mini MX1 |
Supplier - OrangeTek Ltd / Pedestrian Only |
OTEK |
OrangeTek |
|
PX1 |
Terraled Mini PX1 |
Supplier - OrangeTek Ltd / Pedestrian Only |
WE |
WE-EF |
|
P540 |
PFL 540-SE |
Supplier - Mark Herring Lighting |
GO |
Gough (Betacom) |
|
G520 |
GL520 |
Supplier - Betacom Ltd / Premium Driver & 7032 optic only / Pedestrian only |
PHIL |
Philips |
|
GPLS |
Roadstar GPLS |
Supplier - Philips (NZ) Ltd / Vehicle only |
PHIL |
Philips |
|
GPLM |
Roadstar GPLM |
Supplier - Philips (NZ) Ltd / Vehicle only |
PHIL |
Philips |
|
STEL |
Stela+ (gen2) |
Supplier - Kendelier Lighting / Pedestrian only |
SCH |
Schreder |
|
PNO1 |
PIANO 1 |
Supplier - Betacom Ltd |
SCH |
Schreder |
|
PNO2 |
PIANO 2 |
Supplier - Betacom Ltd / Vehicle only |
SCH |
Schreder |
|
TEC1 |
TECEO 1 (5068) |
Supplier - Betacom Ltd |
SCH |
Schreder |
|
TEC2 |
TECEO 2 (5118) |
Supplier - Betacom Ltd / Vehicle Only |
SYLV |
Sylvania |
|
STL |
StreetLED |
Supplier - Aesthetics Lighting / Aero screen only / Pedestrian Only |
Lamp Make: AEC
Lamp Model: 250S
Description: 250w High Pressure Sodium
Lamp Wattage: 250w
Lamp Make: AEC
Lamp Model: 400S
Description: 400w High Pressure Sodium
Lamp Wattage: 400w
Lamp Make: AEC
Lamp Model: F58
Description: 2 x 58w Fluoro
Lamp Wattage: 116w
These changes are effective from 1 June 2021.
CloseLamp Make Code: DW Windsor
Lamp Model: KMID
Description: Kirium Midi
This change is effective from 25 February 2021.
CloseLamp Make Code: HOLO
Lamp Make Description: Holophane
Lamp Model Code: SLIN
Lamp Model Description: S-Line
Lamp Wattage: 68
Explanation: Max. wattage 68w
This change is effective from 19 May 2021.
CloseLamp Make: NVC Lighting New Zealand Ltd
Lamp Model Code: ISC1
Lamp Model Description: ISCO1
Lamp Wattage: 75
Explanation: Max. wattage 75w
Lamp Make: NVC Lighting New Zealand Ltd
Lamp Model Code: ISC2
Lamp Model Description: ISCO2
Lamp Wattage: 100
Explanation: Max. wattage 100w
This change is effective from 19 May 2021.
CloseMake: Schreder
Model: S15T
Description: 150w Sodium Vapour (SON)
Lamp Wattage: 150w
Make: Schreder
Model: S10T
Description: 100w Sodium Vapour (SON)
Lamp Wattage: 100w
These changes are effective from 16 June 2021.
CloseMake: Schreder
Model: S10T
Description: 100w Sodium Vapour
Gear Wattage: 100w
Make: Schreder
Model: S20T
Description: 200w Sodium Vapour
Gear Wattage: 200w
These changes are effective from 16 June 2021.
CloseCode: LMC
Description: Lean-Mix Concrete
Explanation: Lean concrete is a mix where the amount of cement is lower than the amount of liquid, cement content less than about 10 % of the total contents.
This change is effective from 17 May 2021.
The below railing end types are W-beam end treatments.
End style | Description |
MSKT | MASH-SKT. Supplied by Steelgal. |
SFTST | SoftStop MASH TL3. Supplied by Ingal Civil. |
MAXT | MAX-Tension. Supplied by CSP Pacific. |
Changes to rail end types effective 1 October 2019.
Close
Lookup Table |
Lookup Item code |
Lookup Item description |
Lookup Item explanation |
Railing Make |
MASHFLEX |
MashFlex |
|
Railing Make |
MARG |
Margaritelli |
|
Railing Make |
ARMR |
Armourguard |
|
Rail End Style |
CURV |
Curved W-Beam Guardrail Terminal |
Equivalent to NCHRP 250 TL-3 |
Rail End Style |
HERC |
Hercules Crash Cushion |
Test conditions; MASH TL-3 |
Rail End Style |
TL-3 |
Mash TL-3 |
|
Rail End Style |
TL-4 |
Mash TL-4 |
|
Rail End Style |
MFLX |
MashFlex End Terminal |
|
Rail End Style |
RAPT |
Raptor Crash Cushion |
Test conditions; NCHRP 250 TL-1 |
Rail End Style |
SCI10 |
SCI-100 Smart Cushion |
Test conditions; MASH TL-3 and TL-2 |
Rail End Style |
SENM |
Sentryline-M End Terminal |
|
Railing Ground Fix |
ANCR |
Anchor Block |
|
Railing Type |
H1BL |
Aesthetic Barrier H1BL-01 |
Approximately equivalent to MASH TL-2 |
Railing Type |
H2BL |
Aesthetic Barrier H2BL-01 |
Approximately equivalent to MASH TL-3 |
Railing Type |
GATE |
Median Gate System |
Test conditions; NCHRP 350 TL-3 |
Railing Type |
T18 |
T18 Lograil |
T18 Lograil can be 4M or 4MS2 |
Railing Type |
VG300 |
VGAN 300 Bridge Barrier |
Pedestrian bridge barrier |
Railing Type |
VG200 |
VGSH 2000 Bridge Barrier |
Pedestrian bridge barrier |
Railing Type |
VG400 |
VGSH 4000 Bridge Barrier |
Pedestrian bridge barrier |
Railing Material |
ALU |
Aluminium |
|
These changes are effective from 3 June 2021.
CloseCode: DMPS
Description: Discontinuous Motorcyclist Protection System
Explanation: “Post Buffers”. Currently only one formally accepted by NZTA – ImpactProtect from CSP Pacific – 10/03/2020
Changes effective from 10 March 2020.
Surface enrichment and surface rejuvenation are different surface treatments.
Surface enrichment is a light application of binder, with no aggregate applied, sprayed over surfacing that are losing chip or have hard/brittle binder. The binder is not always aged and are usually emulsions with low bitumen contents (and can also be known as Fog Coat). These surfaces can be trafficked within a day or two of application.
Surface rejuvenation is a heavier application of binder, with small aggregate and is used as a bond on older/brittle existing binder. A consequence of this process is filling voids and coating the existing aggregate with binder hence additional aggregate is required to ensure macrotexture is maintained.
Attribute | Code | Description |
Rejuvenation Seal | REJCS | Rejuvenation seal over chip seal |
Rejuvenation Seal | REJAC | Rejuvenation seal over asphalt |
Please note that the allowable surface function is E – Enrichment. Changes effective from 11 February 2019.
CloseCode: AB1
Category: Information General
Description: Emergency Escape Zone
Front Legend: EMERGENCY ESCAPE ZONE ___m LENGTH
This change is effective from 3 February 2021.
CloseCode: AU52
Description: Pass Safely – Cyclists
Category: Warning Miscellaneous
Front Legend [CYCLIST SYMBOL] 1.5m <--> [CAR SYMBOL] PASS SAFELY
This change is effective from 29 June 2022.
CloseCode: RP64
Category: Priority
Description: One Vehicle Per Green Each Lane (Ramp Signals)
Front Legend: ONE VEHICLE PER GREEN EACH LANE
This change is effective from 19 April 2021.
Code: WL5
Category: Miscellaneous
Description: Drive on Left
Explanation: Reflectorised yellow sign with arrows indicating left – Drive on Left supplementary
This change is effective from 14 October 2019.
CloseCode: WU1M
Category: Warning Miscellaneous
Description: Marae warning and supplementary
Front Legend: [PEDESTRIANS SYMBOL] + MARAE
This change is effective from 21 February 2022.
CloseCode: WU22
Category: Permanent Warning
Description: Kura School Supplementary
Front Legend: KURA SCHOOL
This change is effective from 30 May 2022.
CloseCode: WU62
Category: Permanent warning general supplementary
Description: 40km/h advisory – cyclists on narrow road
There is an M30 accepted luminaires [PDF, 343 KB] containing all updated information.
All changes are effective from 1 October 2019.
Wellington City Council have installed black decorative street lights on Cobham Drive (SH1) near the Wellington Airport. This is an approved street light but is not commonly used by the NZ Transport Agency.
Gear make | Gear model - code | Gear model - description | Details of change |
NO GEAR |
NG |
No gear |
Made inactive |
N/A No iear |
NA |
N/A No gear |
Changed from ‘N/A No Gear’ to ‘No Gear’ |
Changes effective from 14 February 2020.
ClosePole make: Spunlite
Pole model: 11M
Description: 11M
This change is effective from 1 February 2021.
ClosePole make
Code | Description | Explanation |
STSC | Streetscape | Streetscape decorative poles – commonly used by Wellington City Council |
Pole model
Code | Description |
PS1 | Streetscape PS1 |
Pole attachment
Code | Description |
DBA | Banner arm (Double bracket) |
Changes made to the lookups are effective from 25 November 2019.
CloseThe PH – Phillips and SYL - Sylvania in the Lamp Make lookup table are now inactive.
Lamp make |
Lamp model |
Description |
Explanation |
Action |
PH - Phillips |
100 |
100 HPS SON/T |
- |
Made inactive |
PH - Phillips |
150 |
150 HPS SON/T |
- |
Made inactive |
PH - Phillips |
250 |
250 HPS SON/T |
- |
Made inactive |
PH - Phillips |
400 |
400 HPS SON/T |
- |
Made inactive |
PH - Phillips |
600 |
600 HPS SON/T |
- |
Made inactive |
PH - Phillips |
70 |
70 HPS SON/T |
- |
Made inactive |
SYL - Sylvania |
100 |
100 HPS SON/T |
- |
Made inactive |
SYL - Sylvania |
150 |
150 HPS SON/T |
- |
Made inactive |
SYL - Sylvania |
250 |
250 HPS SON/T |
- |
Made inactive |
SYL - Sylvania |
250C |
250 HPS SON/T coated |
- |
Made inactive |
SYL - Sylvania |
400 |
400 HPS SON/T coated |
- |
Made inactive |
SYL - Sylvania |
600 |
600 HPS SON/T coated |
- |
Made inactive |
PHIL - Philips |
100S |
100w High Pressure Sodium |
100 HPS SON/T |
NEW |
PHIL - Philips |
150S |
150w High Pressure Sodium |
150 HPS SON/T |
NEW |
PHIL - Philips |
250S |
250w High Pressure Sodium |
250 HPS SON/T |
NEW |
PHIL - Philips |
400S |
400w High Pressure Sodium |
400 HPS SON/T |
NEW |
PHIL - Philips |
600S |
600w High Pressure Sodium |
600 HPS SON/T |
NEW |
PHIL - Philips |
70S |
70w High Pressure Sodium |
70 HPS SON/T |
NEW |
SYLV - Sylvania |
100S |
100w High Pressure Sodium |
100 HPS SON/T |
NEW |
SYLV - Sylvania |
150S |
150W High Pressure Sodium |
150 HPS SON/T |
NEW |
SYLV - Sylvania |
250S |
250w High Pressure Sodium |
250 HPS SON/T |
NEW |
SYLV - Sylvania |
250C |
250w High Pressure Sodium (coated) |
250 HPS SON/T coated |
NEW |
SYLV - Sylvania |
400S |
400w High Pressure Sodium (coated) |
400 HPS SON/T coated |
NEW |
SYLV - Sylvania |
600S |
600w High Pressure Sodium (coated) |
600 HPS SON/T coated |
NEW |
Lamp Make Code – OSRM
Lamp Make Description – OSRAM
Action – Made inactive
The following lamp model codes which were part of the OSRM make have been made inactive:
Lamp Model Code |
Lamp Model Description |
Lamp Wattage |
Changes made to lookup |
230S |
2 x 30w sodium vapour |
60w |
Made inactive |
255S |
2 x 55w sodium vapour |
110w |
Made inactive |
135L |
1 x 35w sodium low pressure |
35w |
Made inactive |
100H |
100w sodium hp |
100w |
Made inactive |
150H |
150w sodium hp |
150w |
Made inactive |
150T |
150w son-t |
150w |
Made inactive |
250H |
25ow High Pressure Sodium |
250w |
Made inactive |
New codes added to the OSRAM (OSRA) lamp make:
Lamp Make Code |
Lamp Make Description |
Lamp Model Code |
Lamp Model Description |
Lamp Wattage |
Changes made to lookup |
OSRA |
OSRAM |
30S |
30w Sodium Vapour |
30w |
NEW |
OSRA |
OSRAM |
55S |
55w Sodium Vapour |
55w |
NEW |
OSRA |
OSRAM |
35L |
35w Low Pressure Sodium |
35w |
NEW |
OSRA |
OSRAM |
100H |
100w High Pressure Sodium |
100w |
NEW |
OSRA |
OSRAM |
250H |
250w High Pressure Sodium |
250w |
NEW |
These changes are effective from 16 June 2020.
CloseAttribute | Code | Description |
Enrichment Seal (application of binder/emulsions) | E | Enrichment |
Asphalt or similar levelling is done prior to final surfacing (not 1st coat, 2nd coat or reseal). | P | Pre-levelling |
Changes effective from 12 October 2017.
Close
Material |
Material |
Function |
Function |
Security Zone |
Default Life for Pavement Use |
|||||||
First Chip Size |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
|||||
ACM |
Dense graded asphalt AC (M/10) |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
ACM |
Dense graded asphalt AC (M/10) |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
ACM |
Dense graded asphalt AC (M/10) |
R |
Reseal |
All Security Zones |
All Chip Sizes |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
DGM |
Dense graded asphalt DG (M/10) |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
DGM |
Dense graded asphalt DG (M/10) |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
DGM |
Dense graded asphalt DG (M/10) |
R |
Reseal |
All Security Zones |
All Chip Sizes |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
BBM |
Bitumen Bound Macadam |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
BBM |
Bitumen Bound Macadam |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
BBM |
Bitumen Bound Macadam |
R |
Reseal |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
OGPAV |
High Voids Open Graded Porous Asphalt |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
OGPAV |
High Voids Open Graded Porous Asphalt |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
OGPAV |
High Voids Open Graded Porous Asphalt |
R |
Reseal |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
UTA |
Ultra Thin Asphalt |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
UTA |
Ultra Thin Asphalt |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
UTA |
Ultra Thin Asphalt |
R |
Reseal |
All Security Zones |
All Chip Sizes |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
EPA |
Epoxy Porous Asphalt (EMOGPA) |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPA |
Epoxy Porous Asphalt (EMOGPA) |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPA |
Epoxy Porous Asphalt (EMOGPA) |
R |
Reseal |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPAHV |
Epoxy Porous Asphalt (EMOGPA) High Volume |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPAHV |
Epoxy Porous Asphalt (EMOGPA) High Volume |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPAHV |
Epoxy Porous Asphalt (EMOGPA) High Volume |
R |
Reseal |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPAHS |
Epoxy Porous Asphalt (EMOGPA) High Strength |
1 |
1st Coat |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPAHS |
Epoxy Porous Asphalt (EMOGPA) High Strength |
2 |
2nd Coat |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
EPAHS |
Epoxy Porous Asphalt (EMOGPA) High Strength |
R |
Reseal |
All Security Zones |
All Chip Sizes |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
Changes effective from 15 January 2018.
CloseCode: DA31
Description: Rhodoval DA310
Explanation: Used in reseals in 20/21 FY.
P52S – PG52 Standard asphalt binder to be applied in cool climate zones.
P52H – PG52 Heavy asphalt binder to be applied in cool climate zones.
P52V – PG52 Very heavy asphalt binder to be applied in cool climate zones.
P52E – PG52 Extreme asphalt binder to be applied in cool climate zones.
P58S – PG 58 Standard asphalt binder to be applied in moderate climate zones.
P58H - PG 58 Heavy asphalt binder to be applied in moderate climate zones.
P58V - PG 58 Very heavy asphalt binder to be applied in moderate climate zones.
P58E - PG 58 Extreme asphalt binder to be applied in moderate climate zones.
P64S – PG 64 Standard asphalt binder to be applied in warm climate zones.
P64H – PG 64 Heavy asphalt binder to be applied in warm climate zones.
P64V – PG 64 Very heavy asphalt binder to be applied in warm climate zones.
P64E – PG 64 Extreme asphalt binder to be applied in warm climate zones.
These changes are effective from 14 April 2021.
CloseCode: RKLC
Description: Rock Lined Channel
Explanation: Rock Lined Surface Water Channel
Code: SIDE
Description: Side Drain
Constructed SWC: Yes
Explanation: SWC Side Drain
A Lane Coverage field has been added to RAMM to assist with tracking the accurate lane kilometre achievement for surfacing renewals across the entire network. Effective from 1 July 2017, this is a mandatory field for ALL surfacing data loaded into RAMM.
CloseLamp Make | Description | Lamp Model | Description | Explanation | Lamp Wattage |
AEC |
AEC |
A2 |
LED A2 LED |
LED varies 37 - 71W |
37 |
AEC |
AEC |
IT1S |
LED ITALO 1 - STA 1 |
LED varies 28.5 - 37.5W |
29 |
AEC |
AEC |
IT17 |
LED ITALO 1 - 7SS |
LED varies 28.5 - 37.5W |
29 |
AEC |
AEC |
IT1 |
LED ITALO 1 |
LED varies 15 - 103W |
15 |
AEC |
AEC |
IT2 |
LED ITALO 2 |
LED varies 60 - 154W |
60 |
AEC |
AEC |
IT3 |
LED ITALO 3 |
LED varies 132 - 289W |
132 |
AEC |
AEC |
LS45 |
LED-in (ST) 4.5 |
LED varies 28 - 145W |
28 |
AEC |
AEC |
LS47 |
LED-in (ST) 4.7 |
LED varies 60 - 118W |
60 |
AEC |
AEC |
LO45 |
LED-in (OC) 4.5 |
LED varies 28 - 145W |
28 |
AEC |
AEC |
LO47 |
LED-in (OC) 4.7 |
LED varies 60 - 118W |
60 |
CREE |
Cree |
LED2 |
LEDway XIL02 |
LED varies 23 - 70W |
23 |
CREE |
Cree |
LED4 |
LEDway XIL04 |
LED varies 45 - 134W |
45 |
CREE |
Cree |
LED7 |
LEDway XIL07 |
LED varies 80 - 203W |
80 |
CREE |
Cree |
LED1 |
LEDway XIL10 |
LED varies 117 - 263W |
117 |
CREE |
Cree |
SQR |
LED EDGE Square |
LED varies 25 - 261W |
25 |
CREE |
Cree |
RND |
LED EDGE Round |
LED varies 45 - 202W |
45 |
CREE |
Cree |
XSP1 |
LED XSP1 |
LED varies 15 - 52W |
15 |
CREE |
Cree |
XSP2 |
LED XSP2 |
LED varies 29 - 168W |
29 |
CREE |
Cree |
XSP3 |
LED XSP1 3M |
LED varies 29 - 34W |
29 |
IGUZ |
iGuzzini |
Wow |
LED Wow |
LED 37W |
37 |
IGUZ |
iGuzzini |
WOOD |
LED Woody |
LED 11 - 17W |
11 |
KTL |
KTL |
B28F |
LED Shard-P B28-F |
LED 28W |
28 |
ROAD |
LED Roadway |
ST24 |
LED Satellite SAT-24S |
LED varies 22 - 50W |
22 |
ROAD |
LED Roadway |
ST48 |
LED Satellite SAT-48S |
LED varies 43 - 100W |
43 |
ROAD |
LED Roadway |
ST72 |
LED Satellite SAT-72M |
LED varies 65 - 150W |
65 |
ROAD |
LED Roadway |
ST96 |
LED Satellite SAT-96M |
LED varies 86 - 200W |
86 |
ROAD |
LED Roadway |
NX12 |
LED NXT-12S |
LED varies 14 - 27W |
14 |
ROAD |
LED Roadway |
NX24 |
LED NXT-24S - 4AH |
LED 28W |
28 |
ROAD |
LED Roadway |
NX36 |
LED NXT-36S |
LED varies 42-80W |
42 |
ROAD |
LED Roadway |
NX48 |
LED NXT-48M |
LED varies 53 - 108W |
53 |
ROAD |
LED Roadway |
NX60 |
LED NXT-60M |
LED varies 65 -133W |
65 |
ROAD |
LED Roadway |
NX72 |
LED NXT-72M |
LED varies 78 - 158W |
78 |
OTEK |
OrangeTek |
MX1 |
LED Terraled Mini MX1 |
LED varies 12 - 36W |
12 |
OTEK |
OrangeTek |
PX1 |
LED Terraled Mini PX1 |
LED varies 12 - 36W |
12 |
WE |
WE-EF |
P540 |
LED PFL 540-SE |
LED varies 48 - 144W |
48 |
GO |
GOUGH (Betacom) |
G520 |
LED - GL520 |
LED varies 29 - 33W |
29 |
PHIL |
Philips |
GPLS |
LED Roadstar GPLS |
LED varies 45 - 102W |
45 |
PHIL |
Philips |
GPLM |
LED Roadstar GPLM |
LED varies 119 - 204W |
119 |
PHIL |
Philips |
STEL |
LED Stela+ (gen2) |
LED 36W |
36 |
SCH |
Schreder |
PNO1 |
LED PIANO 1 |
LED varies 21 - 63W |
21 |
SCH |
Schreder |
PNO2 |
LED PIANO 2 |
LED varies 84 - 128W |
84 |
SCH |
Schreder |
TEC1 |
LED TECEO 1 (5068) |
LED varies 19 - 113W |
19 |
SCH |
Schreder |
TEC2 |
LED TECEO 2 (5118) |
LED varies 62 - 279W |
62 |
SYLV |
Sylvania |
STL |
LED StreetLED |
LED 26.7 W |
27 |
Gear Make | Description | Gear Model | Description | Gear Wattage | Explanation |
PH |
Phillips |
XI-D |
Xitanium - DALI 2.0 |
0 |
LED Driver & Control interface |
PH |
Phillips |
XI-V |
Xitanium - 1-10V |
0 |
LED Driver & Control interface |
PH |
Phillips |
XI-L |
Xitanium - Lineswitch |
0 |
LED Driver & Control interface |
Changes apply from 16 August 2017.
ClosePavement Material | Description | Default Size | Default Minimum | Default Maximum | Explanation | Active |
ETB |
Emulsion Treated Basecourse |
0 |
|
|
Construction of modified basecourse layers using bitumen emulsion. Specification NZTA B/7:2012 Specification for Manufacture and Construction of Plant Mixed Modified Pavement Layers applies. |
True |
FBS |
Foam Bitumen Stabilised |
0 |
|
|
Construction of modified sub-base or basecourse layers using foamed bitumen. Specification NZTA B/7:2012 Specification for Manufacture and Construction of Plant Mixed Modified Pavement Layers applies |
True |
HLAB40 |
Hi-Lab all passing 40mm sieve |
180 |
|
|
Hi-Lab is constructed from coarse graded, large stone aggregate incorporating low cement contents. It is based on a new construction methodology (see NZTA draft/pilot specification and notes for Hi-Lab). |
True |
HLAB50 |
Hi-Lab all passing 50mm sieve |
180 |
|
|
Hi-Lab is constructed from coarse graded, large stone aggregate incorporating low cement contents. It is based on a new construction methodology (see NZTA draft/pilot specification and notes for Hi-Lab). |
True |
HLAB65 |
Hi-Lab all passing 65mm sieve |
180 |
|
|
Hi-Lab is constructed from coarse graded, large stone aggregate incorporating low cement contents. It is based on a new construction methodology (see NZTA draft/pilot specification and notes for Hi-Lab). |
True |
M3 |
M3 Specification |
75 |
40 |
1000 |
The default size and minimum is now 75. |
True |
ACM10 |
Dense graded asphalt AC10 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation AC10 replaces old SAC - Structural Asphaltic Concrete code. |
True |
ACM14 |
Dense graded asphalt AC14 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation AC14 replaces old SAC - Structural Asphaltic Concrete code. |
True |
ACM20 |
Dense graded asphalt AC20 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation AC20 replaces old SAC - Structural Asphaltic Concrete code. |
True |
ACM28 |
Dense graded asphalt AC28 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation AC28 replaces old SAC - Structural Asphaltic Concrete code. |
True |
DG10 |
Dense graded asphalt DG10 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation DG10 replaces old SAC - Structural Asphaltic Concrete code. |
True |
DG14 |
Dense graded asphalt DG14 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation DG14 replaces old SAC - Structural Asphaltic Concrete code. |
True |
DG20 |
Dense graded asphalt DG20 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation DG20 replaces old SAC - Structural Asphaltic Concrete code. |
True |
DG28 |
Dense graded asphalt DG28 (M/10) |
0 |
|
|
M/10 compliant dense graded asphalt base course mix type. Mix designation DG28 replaces old SAC - Structural Asphaltic Concrete code. |
True |
HFAC10 |
High Fatigue Dense Graded Asphalt AC10 (M/10) |
80 |
35 |
140 |
M/10 compliant high fatigue dense graded asphalt base course mix type with high bitumen content. Mix designation AC10 replaces old SAC - Structural Asphaltic Concrete code. |
True |
HFAC14 |
High Fatigue Dense Graded Asphalt AC14 (M/10) |
80 |
50 |
140 |
M/10 compliant high fatigue dense graded asphalt base course mix type with high bitumen content. Mix designation AC14 replaces old SAC - Structural Asphaltic Concrete code. |
True |
HFAC20 |
High Fatigue Dense Graded Asphalt AC20 (M/10) |
80 |
70 |
140 |
M/10 compliant high fatigue dense graded asphalt base course mix type with high bitumen content. Mix designation AC20 replaces old SAC - Structural Asphaltic Concrete code. |
True |
HFAC28 |
High Fatigue Dense Graded Asphalt AC28 (M/10) |
95 |
95 |
140 |
M/10 compliant high fatigue dense graded asphalt base course mix type with high bitumen content. Mix designation AC28 replaces old SAC - Structural Asphaltic Concrete code. |
True |
Pavement Material | Description | Default Size | Default Minimum | Default Maximum | Explanation | Active |
FAB | Fabric | 0 | Made inactive due to being a duplicate code of FABRIC – Fabric. | False | ||
M5 | M5 Specification | 75 | 40 | 1000 | False | |
SAC | Structural asphaltic concrete | 80 | 40 | 200 | Generic SAC replaced by ACM, DG and HFAC codes. Code has been replaced with AC and DG codes. | False |
B/C | Unknown Basecourse | 0 | False |
Changes apply from 27 November 2017.
Close
Power supply company code |
Description |
Action |
EC |
Ecotricity |
NEW |
EK |
Electric Kiwi |
NEW |
EO |
EnergyOnline |
NEW |
FL |
Flick |
NEW |
JE |
Just Energy |
NEW |
ME |
Mercury |
NEW |
MR |
Meridian |
NEW |
NO |
Nova |
NEW |
Work origin is mandatory on all assets entered into the drainage and surface water channel tables from 1 July 2019.
Please note that these fields will need to be accessed through the new interface as Classic RAMM will not be updated.
Class Code |
Activity Class ID |
Category Code |
Work Category ID |
Work Origin Description (NZTA Specific) |
Work Origin Explanation |
Drainage Table |
Surface Water Channel (SWC) Table |
03 |
Walking and Cycling |
451 |
Walking Facilities |
Walking Facilities |
The construction of new / improved footpaths, pedestrian crossing features (including kerb crossings, central refuge and pedestrian platforms), altered kerb lines to improve access and other assets necessary to bring the facility into service. This excludes shared walking & cycling facilities. |
Y |
Y |
03 |
Walking and Cycling |
452 |
Cycling Facilities |
Cycling Facilities |
The construction of on road interventions required to improve the safety and amenity value of cycling, e.g. a widening existing carriageways, vehicle parking configurations, pinch points or kerb structure, separate cycle paths etc. |
Y |
Y |
09 |
State Highway Maintenance |
113 |
Routine Maintenance |
Routine Maintenance |
The routine care of the drainage infrastructure to maintain the structural integrity of drainage assets. This includes activities such as maintenance and repair of surface water channels and subsoils, debris removal to maintain watercourses through culverts, sump maintenance etc. |
Y |
Y |
09 |
State Highway Maintenance |
213 |
Drainage Renewals |
Drainage Renewals |
|
Y |
Y |
09 |
State Highway Maintenance |
113 |
Base Preservation Drainage Length |
Base Preservation Drainage Length |
The objective of the drainage renewals activity is to restore the pavement formation and drainage systems to achieve the objective of keeping pavement layers and subgrade at optimum water content. Base Preservation Drainage Lengths are deemed planned drainage maintenance activities and are funded out of drainage maintenance. This includes high lip removal, clearing and regrading of side drains and reform unlined surface water channels. |
Y |
Y |
13 |
State Highway Improvements |
341 |
Resilience |
Resilience |
Resilience activities which provide for the construction / implementation of low-cost / low-risk improvements (<$300,000). This includes small, isolated geometric road and intersection improvements, traffic calming etc. (was WC231 Associated improvements) |
Y |
Y |
13 |
State Highway Improvements |
341 |
Efficiency |
Efficiency |
Efficiency activities which provide for the construction / implementation of low-cost / low-risk improvements (<$300,000). This includes small, isolated geometric road and intersection improvements, traffic calming etc. (was WC231 Associated improvements) |
Y |
Y |
13 |
State Highway Improvements |
341 |
Safety |
Safety |
Safety activities which provide for the construction / implementation of low-cost / low-risk improvements (<$300,000). This includes small, isolated geometric road and intersection improvements, traffic calming etc. (was WC231 Associated improvements) |
Y |
Y |
99 |
Unfunded Activity Class |
998 |
Unfunded Third Party Work |
Unfunded Third Party Work |
Construction of new assets or replacement of existing assets through third party works, not funded by the Principal (e.g. shopping centre upgrades, power company upgrades etc.). This excludes third party work where cost sharing with the Principal has been agreed. In this case the work is included under the work origin related to the cost sharing. |
Y |
Y |
99 |
Unfunded Activity Class |
999 |
Unfunded Rework |
Unfunded Rework |
Rework is replacing (completely or partially) previously completed work due to poor construction, design, failure of original treatment (e.g. inadequate treatment) where contractual liability still exists. This does not include failure due to factors outside the supplier's control (e.g. weather event, third party damage etc.). The period for rework could be >12 months after initial construction, could include more than one replacement activity and should be identified based on how it is funded and agreed with Principal. |
Y |
Y |